What Pre-Drywall and Phase Inspections Found

Home B: a large hole torn in the house wrap

In short: In pre-drywall inspections of 12 new homes, every home had framing or structural defects that would soon have been hidden behind drywall.

📅 October 30, 2026  •  ⏱️ 14 min read

In pre-drywall inspections of 12 new homes, every home had framing or structural defects that would soon have been hidden behind drywall. Eleven of the 12 had problems with the house wrap or flashing, the layer that keeps water out of the walls.

12 new homes inspected before drywall11 of 12 had house wrap or flashing defects8 of 12 had anchor bolts missing, loose or misplaced

Why inspect before the walls are closed

A pre-drywall inspection happens after framing, roofing, windows and rough plumbing, electrical and HVAC are in, but before insulation and drywall. It’s the only time anyone can see the anchor bolts, truss connections, hangers and flashing that hold the house together and keep it dry. Once the walls close, these defects can only be found by cutting them open.

Four of these homes also had a final-phase inspection before closing, so we could see what happened to the problems flagged earlier.

Each inspection followed the NC Home Inspector Licensure Board Standards of Practice, or the SC standards for homes in South Carolina. Client names and street addresses have been left out.

The homes

Twelve new-construction homes in ten towns across North and South Carolina.

HomeLocationInspections
Home AStatesville, NCPre-drywall
Home BMooresville, NCPre-drywall
Home CIndian Land, SCPre-drywall
Home DGastonia, NCPre-drywall
Home EMooresville, NCPre-drywall and final
Home FWeddington, NCPre-drywall and final
Home GDavidson, NCPre-drywall and final
Home HDavidson, NCPre-drywall and final
Home IHuntersville, NCPre-drywall
Home JCharlotte, NCPre-drywall
Home KFort Mill, SCPre-drywall
Home LHarrisburg, NCPre-drywall

By the numbers

11 of 12 homes had house wrap or flashing defects before siding went on

Number of homes (out of 12) where each issue was found at the pre-drywall inspection

Number of homes, out of twelve, where each issue was found at the pre-drywall inspection
Source: AHI pre-drywall inspection reports. Summary findings only.

Water barrier problems were nearly universal. Missing or loose anchor bolts, bad hanger installs and poorly framed window and door openings each showed up in two of every three homes.

The most significant findings

House wrap and flashing defects (11 of 12 homes)

House wrap was torn, loose, missing in areas or not taped at the seams. Electrical boxes, vents and pipes went through the wall with no flashing, or with flashing that wasn’t secured. At Home B, there was no visible flashing at the front gable windows. At Home F, windows weren’t sealed at the sill and the flashing tape wasn’t bonding. At Home L, a second-floor window already had active water intrusion at the sill, staining the subfloor below. Once siding goes on, fixing these usually means taking the siding back off.

Home B: a large hole torn in the house wrap
Home B: a large hole torn in the house wrap.
Home E: house wrap torn open around a window
Home E: house wrap torn open around a window.
Home J: a tear in the house wrap
Home J: a tear in the house wrap.
Home G: a vent improperly installed and taped through the wrap
Home G: a vent improperly installed and taped through the wrap.
Home B: an electrical box through the wall with no flashing
Home B: an electrical box through the wall with no flashing.
Home F: a window not sealed at the sill
Home F: a window not sealed at the sill.
Home L: active water intrusion at a window sill
Home L: active water intrusion at a window sill.
Home L: water staining on the subfloor below that window
Home L: water staining on the subfloor below that window.

Anchor bolts missing, loose or damaged (8 of 12 homes)

Anchor bolts and straps tie the wall framing to the foundation so the house resists uplift in high winds. We found bolts missing near the ends and splices of the sill plates, bolts with no washers or nuts, nuts left loose and straps not nailed off. At Home H, the sill plate was damaged where a bolt was hammered through. At Homes A and D, installing the bolts had cracked the slab and left voids at the edge.

Home K: an anchor bolt with no washer or nut
Home K: an anchor bolt with no washer or nut.
Home C: no anchor bolt near the end of a sill plate
Home C: no anchor bolt near the end of a sill plate.
Home H: sill plate damaged where an anchor bolt was hammered through
Home H: sill plate damaged where an anchor bolt was hammered through.
Home I: a foundation strap at the sill not nailed off
Home I: a foundation strap at the sill not nailed off.
Home A: slab edge broken out where an anchor bolt popped through
Home A: slab edge broken out where an anchor bolt popped through.
Home D: cracking and a void in the slab at an anchor bolt
Home D: cracking and a void in the slab at an anchor bolt.

Trusses damaged, bowed or field-repaired (6 of 12 homes)

Six homes had cracked, bowed or damaged trusses or gusset plates. At Home E, a truss above a bathroom was cracked and two trusses over the stairwell were bowing. At Home D, a truss member above the bonus room was badly bowed. At Home F, trusses had already been repaired on site. Truss repairs need a method from the truss manufacturer or a licensed structural engineer, and before drywall is the time to get that letter.

Home E: a cracked truss above the bathroom
Home E: a cracked truss above the bathroom.
Home E: trusses bowing over the stairwell
Home E: trusses bowing over the stairwell.
Home D: a truss member bowing above the bonus room
Home D: a truss member bowing above the bonus room.
Home B: a damaged truss and gusset plate
Home B: a damaged truss and gusset plate.
Home C: a cracked truss member
Home C: a cracked truss member.
Home G: a damaged gusset plate
Home G: a damaged gusset plate.
Home F: a truss already repaired on site
Home F: a truss already repaired on site.

Hangers and hurricane ties missing or installed wrong

Eight homes had joist or truss hangers that were missing, the wrong size or missing nails. At Home L, I-joists above a bathroom had no hangers at all. Four homes had hurricane clips missing or loose, including at the covered porch roof at Home H. These connections hold the roof and floors in place, and all of them disappear behind insulation and drywall at the next stage.

Home D: a truss with no hurricane clip
Home D: a truss with no hurricane clip.
Home C: a hurricane tie loose and missing fasteners
Home C: a hurricane tie loose and missing fasteners.
Home H: hurricane clips missing at the porch roof
Home H: hurricane clips missing at the porch roof.
Home K: the wrong size hanger for the floor framing
Home K: the wrong size hanger for the floor framing.
Home K: hanger issues at the stair floor framing
Home K: hanger issues at the stair floor framing.
Home E: a truss hanger installed improperly
Home E: a truss hanger installed improperly.
Home C: a floor truss hanger installed incorrectly
Home C: a floor truss hanger installed incorrectly.
Home L: I-joists installed without hangers
Home L: I-joists installed without hangers.
Home I: hanger nails not driven as required
Home I: hanger nails not driven as required.

Beams, LVLs and load paths (5 of 12 homes)

Beams and LVLs (engineered lumber beams) carry concentrated loads, so the posts and studs under them have to carry that weight all the way down to the foundation. At Home D, an LVL in the basement had no clear support path down to the slab, and the studs under the garage door header had large gaps. At Home E, the jack studs under the main beam were gapped and notched, two floor systems met over the stairwell without proper support, and the squash blocks weren’t touching the floor above. At Home C, several spots didn’t carry the load from the attic down to the foundation, and a floor support was held only by a strap and nails. At Homes G and L, hangers on an LVL or laminated beam were missing nails, and Home G’s covered porch was still sitting on temporary posts. A beam that isn’t fully supported can sag over time, and once the walls are closed nobody can see why.

Home D: an LVL in the basement with no clear support down to the slab
Home D: an LVL in the basement with no clear support down to the slab.
Home D: gaps in the studs under the garage door header
Home D: gaps in the studs under the garage door header.
Home E: a gapped, notched jack stud under the main beam
Home E: a gapped, notched jack stud under the main beam.
Home E: two floor systems meeting with no proper support
Home E: two floor systems meeting with no proper support.
Home E: squash blocks not touching the floor above
Home E: squash blocks not touching the floor above.
Home E: gapped cripple studs carrying load at the garage wall
Home E: gapped cripple studs carrying load at the garage wall.
Home C: a load from above not carried down to the foundation
Home C: a load from above not carried down to the foundation.
Home C: another break in the load path
Home C: another break in the load path.
Home C: a floor support held only by a strap and nails
Home C: a floor support held only by a strap and nails.
Home G: hangers on an LVL beam missing nails
Home G: hangers on an LVL beam missing nails.
Home L: I-joist hangers on a laminated beam missing nails
Home L: I-joist hangers on a laminated beam missing nails.
Home G: temporary posts holding up the covered porch
Home G: temporary posts holding up the covered porch.

Window and door framing cut short or gapped (8 of 12 homes)

King, jack and cripple studs around windows and doors were cut short or left with gaps, so they don’t carry the load from the header down to the floor. Once drywall goes up, this can show up as a bowed wall or a window or door that sags.

Home A: a gap in the framing at a window
Home A: a gap in the framing at a window.
Home B: window framing studs cut short
Home B: window framing studs cut short.
Home E: a king stud gapped at a window header
Home E: a king stud gapped at a window header.
Home J: a gap at the cripple studs over the front window
Home J: a gap at the cripple studs over the front window.
Home K: gapped cripple studs over the rear door
Home K: gapped cripple studs over the rear door.

Wall framing and stairs

Six homes had studs that were warped, cracked, damaged or gapped at their connections. At Home K, an exterior wall had been cut by another trade and had gaps of 1/4″ to 1/2″ at the plates. At Home H, a damaged stud between the garage and mud room was loose. At Home J, the stairwell landing was damaged.

Home A: damaged, gapped wall framing
Home A: damaged, gapped wall framing.
Home B: framing with gaps at the connections
Home B: framing with gaps at the connections.
Home H: a damaged, loose stud between the garage and mud room
Home H: a damaged, loose stud between the garage and mud room.
Home K: gaps in an exterior wall at the plates
Home K: gaps in an exterior wall at the plates.
Home J: a damaged stairwell landing
Home J: a damaged stairwell landing.

Floors and subfloors (5 of 12 homes)

At Home E, the kitchen floor system sloped and popped when walked on. At Home K, the second floor sloped between a bedroom and the hallway. Homes A and C had uneven or buckling subfloor seams, and Home B had bumps in the floor surface and missing I-joist blocking in the crawl space. Left alone, uneven subfloors can lead to squeaks and damage to the finished flooring.

Home C: uneven, buckling subfloor seams
Home C: uneven, buckling subfloor seams.
Home K: a level showing the second floor sloping
Home K: a level showing the second floor sloping.
Home E: the sloping kitchen floor system
Home E: the sloping kitchen floor system.
Home A: a raised, uneven subfloor seam
Home A: a raised, uneven subfloor seam.
Home B: I-joist blocking missing in the crawl space
Home B: I-joist blocking missing in the crawl space.

Slabs, foundations and piers (6 of 12 homes)

Home B had cracks in the concrete foundation wall. Home C had cracking at the foundation with building materials exposed to the outside. At Home K, the slab was damaged and being repaired during the inspection, which calls for an engineer’s letter afterward. At Home L, the crawl space block walls showed staining from moisture and one block pier was undersized.

Home B: a crack in the concrete foundation wall
Home B: a crack in the concrete foundation wall.
Home C: cracking at the foundation with building materials exposed
Home C: cracking at the foundation with building materials exposed.
Home K: slab damage being repaired during the inspection
Home K: slab damage being repaired during the inspection.
Home L: dark staining from moisture on the crawl space block wall
Home L: dark staining from moisture on the crawl space block wall.
Home L: an undersized block pier
Home L: an undersized block pier.

Roof and sheathing

At Home J, shingles were missing on the front roof and there was a hole through the roof sheathing, so water could get straight in. Home J also had deflection in the gable end sheathing and damaged radiant-barrier foil on the roof deck. At Home G, exterior wall sheathing was missing or damaged.

Home J: missing shingles on the front roof
Home J: missing shingles on the front roof.
Home J: a hole through the roof sheathing
Home J: a hole through the roof sheathing.
Home J: deflection in the gable end sheathing
Home J: deflection in the gable end sheathing.
Home J: damaged radiant barrier foil on the roof sheathing
Home J: damaged radiant barrier foil on the roof sheathing.
Home G: exterior sheathing missing or damaged

Plumbing and HVAC rough-ins

At Home J, the second-floor tubs were set without the mortar bed most manufacturers require, and shower valves were loose in their walls. Shower controls were also loose at Home F. Home D had a chipped fiberglass tub. At Home I, an AC suction line was damaged and left uncapped, which lets debris into the system. Homes A and J had flex ducts kinked badly enough to restrict airflow.

Home J: a tub set with no mortar bed under it
Home J: a tub set with no mortar bed under it.
Home J: a shower valve not secured
Home J: a shower valve not secured.
Home F: a loose shower control
Home F: a loose shower control.
Home D: a chipped fiberglass tub
Home D: a chipped fiberglass tub.
Home I: an AC suction line damaged and left uncapped
Home I: an AC suction line damaged and left uncapped.
Home J: a flex duct kinked through an I-joist
Home J: a flex duct kinked through an I-joist.
Home A: a supply duct heavily kinked
Home A: a supply duct heavily kinked.

Fire safety and air sealing

Homes B and E were missing fire caulking where wires and pipes pass between floors. That caulking slows fire and smoke from spreading through the walls. At Homes A and H, daylight was visible through gaps that should have been foam-sealed, which lets outside air in once the house is finished.

Home B: a penetration between floors with no fire caulking
Home B: a penetration between floors with no fire caulking.
Home E: another missing fire caulk seal
Home E: another missing fire caulk seal.
Home H: daylight showing through gaps that should be foam-sealed
Home H: daylight showing through gaps that should be foam-sealed.

Microbial growth on framing (4 of 12 homes)

Homes F, I, K and L had discoloration and microbial growth on trusses or framing from lumber getting wet during construction. We recommend having it evaluated and cleaned before insulation and drywall seal it in.

Home F: microbial growth on a truss
Home F: microbial growth on a truss.
Home L: microbial growth on framing
Home L: microbial growth on framing.
Home I: discoloration and growth on trusses
Home I: discoloration and growth on trusses.

Decks

At Home E, the deck ledger was only nailed to the house, the joist hangers were installed incorrectly, the posts were missing nails and there was no lateral bracing. At Home B, deck ledger bolts were missing their nuts and washers. A deck ledger that isn’t bolted can pull away from the house.

Home E: deck joist hangers installed incorrectly
Home E: deck joist hangers installed incorrectly.
Home E: a deck post support missing nails
Home E: a deck post support missing nails.
Home B: deck ledger bolts missing nuts and washers
Home B: deck ledger bolts missing nuts and washers.

Grading and drainage

At Home J, the yard sloped toward the house and water was standing next to the foundation. Home I was built on fill soil, with an eroding bank about 18 feet from the rear corner. Home H had erosion around the house. Grading is often unfinished at this stage, but slopes like these need to be corrected before landscaping.

Home J: standing water where the yard slopes toward the house
Home J: standing water where the yard slopes toward the house.
Home I: an eroding fill-soil bank behind the house
Home I: an eroding fill-soil bank behind the house.
Home H: erosion around the house
Home H: erosion around the house.

What the final inspections found

Four homes had a second inspection at the end of construction. Each one still turned up new problems, and three showed that items flagged at the pre-drywall visit hadn’t been fixed.

  • Home E: at pre-drywall, the deck ledger was only nailed to the house. At the final, it was still missing its lag bolts, and some deck joist hangers were still missing fasteners. Sections of the roof covering were also still missing.
  • Home F: wood debris flagged in the crawl space at pre-drywall was still there at the final. The final also found unsupported PEX supply lines and missing crawl space insulation.
  • Home G: the final found a leaking cold-water supply line in a bathroom, second-floor ducts blowing heat when the first-floor thermostat was running, and missing ceiling insulation shown by thermal imaging.
  • Home H: the damaged concrete driveway flagged at pre-drywall was still damaged at the final. The final also found a clogged waste line, a dishwasher that wouldn’t close, and thermal imaging showing poor insulation above the laundry room.
Deck ledger and joist hangers at the rear deck of Home E at the final inspection

Home E at the final: the deck ledger, still not lag-bolted to the house.

A re-inspection is the only way to know a flagged item was actually corrected.

Timing matters

Three inspections show why the visit has to happen at the right moment. At Home A, insulation had already been installed in the exterior walls and parts of the ceiling, hiding framing we needed to see. At Home E, the windows and exterior doors weren’t in yet, which limited the inspection. At Home G, workers had cut the water supply line during the visit, so the plumbing couldn’t be tested under pressure. The best time is after the rough-ins are done and before any insulation goes in.

What this means for buyers

The most important parts of a new home are visible for only a short window during construction. Every home in this study had structural or framing defects at the pre-drywall stage, and each buyer got a photo-documented report to hand the builder while the fixes were still easy.

  • Ask your builder when insulation is scheduled. Book the pre-drywall inspection after the rough-ins are done and before insulation goes in.
  • Get it in writing. For truss damage, missing anchor bolts or hanger problems, ask for the manufacturer’s repair method or an engineer’s letter.
  • Inspect again before closing. A final inspection confirms the earlier items were corrected and catches the finish-out problems that come later.
  • Come back at month 11. A 1-year builder warranty inspection catches what shows up after the first few seasons, while it’s still covered.

Building a new home?

Book your pre-drywall inspection before the insulation goes in. Schedule

Or call 866-356-2363

Scroll to Top