Fresh Paint, Hidden Problems: What 12 Flipped Home Inspections Found

Renovated white farmhouse-style home in Lincolnton, NC listed as a flip before its home inspection

In short: 12 flipped homes near Charlotte had 834 defects behind fresh paint, from patchwork crawl space repairs to bad wiring. See the photos and what buyers found.

📅 November 3, 2026  •  ⏱️ 39 min read

We pulled 12 inspection reports on flipped homes across the Charlotte region. Every one looked move-in ready. Our inspectors documented 834 defects, about 70 per house, and all 12 had structural, electrical, plumbing and exterior problems.

Renovated white farmhouse-style home in Lincolnton, NC listed as a flip before its home inspection
Home K, a renovated two-story more than 100 years old in Lincolnton. The crawl space told a different story.

Table of Contents

The homes at a glance

Homes inspectedDefects documentedAverage per homeSerious enough for the summary
12834About 70314

A flip is built to show well. The money goes where buyers look: paint, flooring, kitchens, baths and lighting. A renovated kitchen and fresh finishes can make a house look brand-new, but they don’t guarantee that repairs were done correctly or that the structure and major systems are sound. In this study, most of the serious problems were in places a renovation rarely touches: the crawl space, the attic and the electrical panel.

Renovated flipped home in Salisbury, NC
Home A · Salisbury
Renovated flipped home in Salisbury, NC
Home B · Salisbury
Renovated flipped home in Mooresville, NC
Home C · Mooresville
Renovated flipped home in Mooresville, NC
Home D · Mooresville
Renovated flipped home in Charlotte, NC
Home E · Charlotte
Renovated flipped home in Cornelius, NC
Home F · Cornelius
Renovated flipped home in Salisbury, NC
Home G · Salisbury
Renovated flipped home in Charlotte, NC
Home H · Charlotte
Renovated flipped home in Charlotte, NC
Home I · Charlotte
Renovated flipped home in China Grove, NC
Home J · China Grove
Renovated flipped home in Lincolnton, NC
Home K · Lincolnton
Renovated flipped home in Salisbury, NC
Home L · Salisbury
HomeLocationType and age
Home ASalisbury, NCRanch, over 50 years old
Home BSalisbury, NCRanch, over 50 years old
Home CMooresville, NCRanch, over 50 years old
Home DMooresville, NCRanch with detached garage apartment, over 50 years old
Home ECharlotte, NCRanch, over 25 years old
Home FCornelius, NCTwo-story, over 25 years old
Home GSalisbury, NCRanch, over 50 years old
Home HCharlotte, NCTwo-story, over 25 years old
Home ICharlotte, NCTwo-story, over 25 years old
Home JChina Grove, NCRanch, over 50 years old
Home KLincolnton, NCTwo-story, over 100 years old
Home LSalisbury, NCRanch, over 50 years old

Each inspection followed the NC Home Inspector Licensure Board Standards of Practice. Client names and street addresses have been left out.

By the numbers

Bar chart: all 12 flipped homes had structural, electrical, plumbing and exterior problems; 11 had attic framing and heating or cooling defects; 9 had kitchen appliance problems
Number of the 12 homes with each finding · AHI inspection reports
CategoryAll defectsIn report summariesHomes
Exterior, decks, drainage and garage doors1676012 of 12
Electrical1266512 of 12
Plumbing and water heaters943412 of 12
Interior finishes91412 of 12
Structure and foundation826112 of 12
Ventilation and insulation692112 of 12
Heating, cooling and gas571211 of 12
Roof, flashing and gutters511012 of 12
Safety482511 of 12
Moisture and microbial growth331911 of 12
Kitchen appliances1639 of 12
Total83431412 of 12

The report summary lists the items NC rules require there: anything not functioning as intended, affecting habitability or needing a specialist. The other 520 are repair items from the body of each report, and many of them are in the finish work buyers see on a walk-through.

What our inspectors found

Rot painted over instead of replaced

Repair · Exterior · Siding and trim

At Home H, a two-story in Charlotte, rotted and buckled composite siding and trim had been painted over or masked instead of replaced. Much of it was still soft when our inspector probed it, a sign the framing behind it may be damaged too. From the street, it looked like a fresh exterior.

Rotted exterior trim painted over on a flipped home in Charlotte, NC
Home H: rotted trim, soft when probed, under fresh paint

A crawl space full of patchwork repairs

Repair · Structure · Floor framing

Under Home A in Salisbury, the floor system was a patchwork of sistered and spliced joists that weren’t properly connected. Temporary wood posts were holding up the floor, added piers were dry-stacked brick and block that had started to lean, and joist hangers were missing fasteners or held with wood screws. Upstairs, the house had been fully refinished.

Patchwork floor joist repairs in the crawl space of a flipped home in Salisbury, NC
Home A: sistered and spliced joists without proper connections

Piers stacked with no footing and no mortar

Repair · Structure · Piers

Seven of the twelve homes had added supports or earlier structural repairs that weren’t done to standard. At Homes B, J and K, block piers had been added under the floor with no concrete footing, little or no mortar, and in some cases the blocks laid on their sides. Piers built this way can shift and settle, and the floors above them move with them.

Concrete block pier with no footing or mortar in a crawl space
Home B: an added block pier with no footing and no mortar

Temporary posts left holding up the floor

Repair · Structure · Supports

Homes A, G and J all had temporary wood posts supporting the floor framing. Posts like these are meant to hold things up during a repair, not to stay in place for good. Permanent supports should be masonry on proper footings.

Temporary wood support post on a loose block in a crawl space
Home G: a temporary wood post set on a loose block

Beam repairs that left gaps

Repair · Structure · Beams

At Home K, a two-story more than a century old in Lincolnton, the main beams had been repaired, but the new and old members weren’t fastened together properly and gaps were left between them. The beams under the master bath had also been cut by a tradesman, and some were missing hangers or ledger strips.

Gap between old and new main beam after a crawl space repair
Home K: gaps between the old and new main beams

Leaning piers and adjustable steel columns

Repair · Structure · Piers

Home L in Salisbury had leaning, unsupported brick piers, adjustable steel columns carrying the floor, joist hangers installed with nothing to fasten into, and framing sagging under a bedroom. Its kitchen ceiling drywall was cracked and loose, a common sign of movement below.

Leaning brick pier supporting a floor girder in a crawl space
Home L: a leaning brick pier in the crawl space

A removed chimney and a ridge patched with wood screws

Repair · Attic · Roof framing

At Home B, a chimney had been taken out and the roof ridge above it repaired with wood screws instead of framing fasteners, leaving a large gap. A rafter beside it was cracked and shifting. Eleven of the twelve homes had damaged, cut or poorly connected roof framing.

Roof ridge framing repaired with wood screws where a chimney was removed
Home B: ridge repair over a removed chimney

Gusset plates coming loose

Repair · Attic · Trusses

Gusset plates are the metal plates that hold truss members together. At Home H, most of the plates along the ridge had come loose, letting the truss members move. Homes C, G and I also had damaged trusses or gusset plates.

Loose metal gusset plates on roof trusses in an attic
Home H: damaged, loose gusset plates at the ridge

A rafter cut through for a vent pipe

Repair · Attic · Rafters

At Home J in China Grove, a rafter had been cut all the way through to make room for a plumbing vent. A cut rafter no longer carries its share of the roof, and the roof can sag at that spot over time.

Roof rafter cut through to fit a plumbing vent pipe in an attic
Home J: a rafter cut through around a plumbing vent

Decay and microbial growth under the floor

Repair · Crawl space · Moisture

Nine homes had microbial growth on the crawl space framing, a sign of past or present high moisture that can weaken the wood. At Home C in Mooresville, the joists and main supports were cupped and decayed. Homes F, H and J also had microbial growth noted elsewhere in the structure, at Home F in the half bath.

Decayed floor joists and microbial growth in a damp crawl space
Home C: floor framing decayed from long-term moisture

Missing vapor barriers

Repair · Crawl space · Vapor barrier

A vapor barrier keeps ground moisture out of the crawl space. At Home A it was missing from more than half the crawl space, with elevated moisture in the floor framing above. Home D’s was missing entirely, and Homes B, C, J, K and L had barriers that were torn, displaced or missing in areas.

Crawl space with no vapor barrier over bare soil
Home A: bare dirt where the vapor barrier is missing

A Zinsco panel left in place

Safety · Electrical · Panel

Every one of the twelve homes had electrical defects. Home B still had a Zinsco panel, a brand with known reliability and safety problems, along with undersized wire on a breaker and an HVAC disconnect with multiple wires under one lug.

Zinsco electrical panel in a renovated home
Home B: a Zinsco electrical panel

Neutral and ground bonded together

Safety · Electrical · Subpanels

In a subpanel, neutral and ground wires must be kept separate. At Homes A, C, D and G they were bonded together, which lets current run back over the ground wire. Homes B, C and D also had wires too small for their breakers, and Homes A, C and G had double-tapped breakers.

Neutral and ground wires bonded together in an electrical subpanel
Home A: neutral and ground bonded in the kitchen subpanel

Smoke detectors swapped out or missing

Safety · Electrical · Smoke detectors

At Home H, hard-wired smoke detectors had been replaced with battery units and the old wiring left loose in the ceiling. Smoke detectors were missing from bedrooms or hallways at six homes, and four homes had no carbon monoxide detector.

Ceiling with loose wiring where a hard-wired smoke detector was replaced
Home H: loose wiring left where a hard-wired detector was removed

Outlets wired wrong or unprotected

Safety · Electrical · Outlets

Two garage outlets at Home G were wired with an open neutral. Outlets were ungrounded in six homes, and outlets in bathrooms, laundries or garages weren’t GFCI protected in eight. Dead outlets turned up in at least four.

Outlet tester showing an open neutral at a garage outlet
Home G: a garage outlet wired with an open neutral

Exposed wiring under new kitchen sinks

Repair · Electrical · Wiring

In kitchens that had just been redone, Homes A, C and H had wiring left exposed under the sink or in the laundry, where cable should be protected. Open splices or uncovered junction boxes turned up in the attics or crawl spaces of Homes A, C, D and G.

Exposed electrical wiring under a renovated kitchen sink
Home H: exposed wiring under the kitchen sink

New fixtures installed wrong

Safety · Electrical · Fixtures

The hall bathroom light fixture at Home I wasn’t properly installed, a fire and safety hazard. Bedroom ceiling fans rocked in their mounts at Homes C and H, and a porch fan at Home E. These are the kind of new-looking fixtures buyers notice and assume are fine.

Bathroom vanity light fixture improperly installed
Home I: a bathroom light fixture not properly installed

Polybutylene left behind new fixtures

Repair · Plumbing · Supply lines

New faucets and fixtures often sat on old supply lines. Homes B, F and G still had polybutylene piping, a product known for failures that is no longer approved. At Home B, PEX lines also ran right next to the gas water heater flue.

Polybutylene water supply piping in a crawl space
Home B: polybutylene supply piping

An active leak above a finished ceiling

Repair · Plumbing · Leaks

At Home H, a stain on the living room ceiling under the master bath read 19% or higher on the moisture meter, meaning the leak was still active. Six homes had plumbing leaks during the inspection.

Thermal camera checking an active leak in a living room ceiling
Home H: checking an active leak below the master bath

A waste line left open

Repair · Plumbing · Drains

At Home F in Cornelius, a waste line had been repaired and left open, which can let sewer gas into the house. Its jack-and-jill sink drained through an S-trap and a ribbed flex drain, and Home K’s plumbing vent appeared to be capped.

Open, improperly repaired drain line in a crawl space
Home F: an improperly repaired waste line left open

Toilets loose or set without clearance

Repair · Plumbing · Toilets

In remodeled bathrooms, toilets at Home D were set without the required clearance to the wall and fixtures beside them. Toilets were loose at the floor at Homes C, E and F, and running at Homes D and F.

Tape measure showing a bathroom toilet installed without required clearance
Home D: a toilet set without the required clearance

Leaking showers and loose fixtures

Repair · Plumbing · Showers

At Home K, an unsealed gap between the shower pan and the glass panel let water out onto the floor. Home F’s shower head and arm were loose in the wall, Home H’s tub spout was loose with a gap at the wall, and shower heads leaked at Homes E and F.

Gap between a shower pan and glass panel letting water escape
Home K: an unsealed gap at the shower glass

Gas and combustion problems

Safety · Gas · Furnace and water heaters

At Home I there was a gas odor at the furnace connection, and our gas detector picked up a reading. Home E’s furnace vent showed poor venting with a failing repair, which can let carbon monoxide into the home. Home G’s gas water heater was closed in a laundry closet with no combustion air.

Gas detector reading at a furnace gas connection in an attic
Home I: a gas detector reading at the furnace connection

Floating floors buckling and lifting

Repair · Interior · Flooring

New flooring is one of the first things a flip gets. At Homes C, E, H and I, the floating floors were already buckling, lifting or warping, and subfloors popped, creaked or sagged in seven homes.

New floating floor planks lifting and separating
Home E: floating floor planks lifting and separating

Cabinets hung with the wrong fasteners

Repair · Interior · Cabinets

Kitchen and bath cabinets were hung with the wrong type of fastener at Homes A, C, E, H and J. Doors that rubbed, wouldn’t latch or were missing hardware showed up in eleven of the twelve homes.

Kitchen wall cabinet hung with improper fasteners
Home E: a wall cabinet hung with the wrong type of fastener

New appliances that didn’t work

Repair · Appliances · Kitchen

Nine homes had kitchen appliance problems, most of them in appliances that looked brand-new. Home C’s oven didn’t work, Home F’s range showed an error and wouldn’t turn on, Home H’s garbage disposal didn’t work, and Home G’s oven smoked heavily enough to set off smoke alarms. Home B’s dishwasher wasn’t secured to the cabinet.

Stainless range showing a C-d0 error code
Home F: the range showed a C-d0 error and wouldn’t turn on

Ranges not anchored against tipping

Safety · Appliances · Range

Ranges at Homes A, F and G weren’t anchored against tipping. That’s a serious hazard if a child stands on an open oven door, and it takes a few minutes to fix.

New range installed without an anti-tip bracket
Home G: a range not anchored against tipping

Decks not built or attached correctly

Safety · Exterior · Decks

Five homes had decks that weren’t built or attached correctly. Home F’s deck had no flashing at the house, cracked joists and stairs pulling away. Home C’s sat on precast blocks at grade, and Homes G, K and L had girders held on with nails only or joists with no hangers.

Deck ledger board attached to a house without flashing
Home F: deck ledger attached without flashing

Ground sloping toward the house

Repair · Exterior · Drainage

Grading, walkways or slabs sloped toward the house at seven homes, sending water toward the foundation, and downspouts were missing extensions at seven homes. Water at the foundation is how many of the crawl space problems start.

Yard graded toward the foundation of a house
Home A: ground sloping toward the house

A compromised garage fire wall

Safety · Garage · Fire separation

The wall between an attached garage and the house is a fire barrier. At Homes F and I it had been compromised. Home F also had a keyed deadbolt that could slow an exit in a fire, and Home I’s garage door opener didn’t reverse when it met resistance.

Damaged fire-rated wall between a garage and living space
Home F: the fire separation between garage and house compromised

What this meant for the buyers

Each buyer got a photo-documented report to use before their due diligence period ended. With it, they could:

  • Negotiate repairs or a price reduction based on documented problems, not guesses.
  • Ask the seller for permits, invoices and engineer’s letters for structural, electrical and plumbing work.
  • Bring in a licensed structural contractor or engineer, electrician and plumber before the due diligence period ended.
  • Have the repairs re-inspected before closing to confirm they were actually made, and made correctly.
  • Walk away if the hidden problems outweighed the new finishes.

Why flipped homes need inspections

Cosmetic renovations can make a property look brand-new, but they don’t guarantee that repairs were completed correctly or that major systems are functioning properly. A professional home inspection helps buyers understand the property’s real condition, prioritize repairs and make an informed decision before closing.

Every defect, by category

All 834 defects from the 12 reports. Items marked SUMMARY were serious enough for the report summary.

Exterior, decks, drainage and garage doors (167 defects · 12 of 12 homes)
HomeDefect
Home AOverdriven, exposed fasteners in the exterior trimSUMMARY
Home AGaps in the rear soffit panelSUMMARY
Home ARear steps settling, cracking and missing a handrailSUMMARY
Home AFront walkway sloped toward the houseSUMMARY
Home AGround sloped toward the house at the front, rear and sidesSUMMARY
Home ADamaged, loose metal trim and siding
Home AMissing or deteriorated exterior sealant
Home ADeteriorated composite trim at the front
Home AWood fascia beginning to deteriorate in many areas
Home AShutters installed with wood screws, paint bubbling
Home ARear door missing weather-stripping
Home ACrawl space door failing and falling when opened
Home AGravel driveway thin, eroded and potholed
Home AShrubs and trees against the house
Home BGround graded toward the houseSUMMARY
Home BStone veneer not installed to current standards
Home BMissing or deteriorated exterior sealant
Home BDamaged, loose vinyl siding
Home BDamaged, loose metal fascia wrap
Home BLoose, buckling rear soffit
Home BFront door has to be forced to latch
Home BCrawl space door catching on exposed framing
Home BStone porch floor cracking at the mortar joints
Home BLarge trees and roots near the foundation
Home BTree limbs touching the roof
Home CMoisture-damaged, deteriorating fascia and soffitsSUMMARY
Home CCracked living room window paneSUMMARY
Home CRotted window frame at the rearSUMMARY
Home CDeck set on precast blocks at gradeSUMMARY
Home CDeck joists not properly attachedSUMMARY
Home CSmall cracks in the brick
Home CMissing or deteriorated exterior sealant
Home CSiding touching the roof
Home CRusting steel lintels
Home CFogged windows with failed seals at most windows
Home CBrick steps separating from the porch
Home CDeck rim board lower than the deck boards
Home CDeck posts in soil, darkened by moisture
Home CGround graded toward the house
Home CTree limbs touching the roof
Home DVinyl siding loose and pulling awaySUMMARY
Home DVinyl siding damaged in many areasSUMMARY
Home DCrawl space door not fitting, with damaged hardwareSUMMARY
Home DFront steps with failing mortar; one section shifts underfootSUMMARY
Home DGround sloped toward the houseSUMMARY
Home DDetached unit: ground sloped toward the buildingSUMMARY
Home DDetached unit: damaged siding with a gap to the interiorSUMMARY
Home DDetached unit: deck piers without bracingSUMMARY
Home DDetached unit: large gap between the steps and the wallSUMMARY
Home DDetached unit: damaged upper sliding glass doorSUMMARY
Home DGaps at window trim end caps
Home DDamaged, loose metal fascia wrap
Home DFogged windows with failed seals
Home DDaylight showing around the rear door
Home DExposed fasteners and damage at the rear door trim
Home DDriveway heaving and settling
Home DLoose deck board
Home DTree limbs touching the roof
Home DEvidence of an underground oil tank
Home DDetached unit: tree limbs touching the roof
Home DDetached unit: damaged, loose metal fascia wrap
Home DDetached unit: daylight showing around the entry doors
Home DDetached unit: loose door kick plate
Home EDamaged vinyl sidingSUMMARY
Home EDamaged rear soffit with gapsSUMMARY
Home ETree limbs touching the roofSUMMARY
Home EMissing or deteriorated exterior sealant
Home EMissing metal fascia wrap, with gaps
Home ELoose shutters
Home EFogged window with a failed seal
Home EDamaged front door weather stripping
Home EEroding concrete slab at the front
Home FEIFS (synthetic stucco) cladding, prone to hidden moistureSUMMARY
Home FEarlier exterior patches cracking and separating; siding touching the roofSUMMARY
Home FRotted, warped rear French doorSUMMARY
Home FMoisture-damaged, loose crawl space doorSUMMARY
Home FDeck missing lateral bracingSUMMARY
Home FDeck girders held on with nails onlySUMMARY
Home FDeck ledger not properly attached and not flashedSUMMARY
Home FCracked, twisting deck joistsSUMMARY
Home FDeck ledger strip missing nailsSUMMARY
Home FDeck stairs pulling awaySUMMARY
Home FLoose deck railings and warped balustersSUMMARY
Home FTree limbs touching the roofSUMMARY
Home FDamaged garage door frame; wheel out of its trackSUMMARY
Home FGarage door track and roller problemsSUMMARY
Home FPeeling paint and long-term moisture damage at rear trim
Home FFogged window with a failed seal
Home FDamaged door weather stripping
Home FGarage entry door missing security screws
Home FRear door rubbing
Home FEroding, settling garage slab and driveway
Home FLarge trees and roots near the foundation
Home FLow area that may need a drain
Home GDamaged, poorly installed vinyl sidingSUMMARY
Home GMissing fascia wrap leaving framing exposedSUMMARY
Home GFront porch slab sloped toward the houseSUMMARY
Home GWalkway heaved by tree rootsSUMMARY
Home GSettled garage slab with a steep stepSUMMARY
Home GDeck girders held on with nails onlySUMMARY
Home GLoose, damaged deck step boardsSUMMARY
Home GRear canopy built incorrectly and tied into the sidingSUMMARY
Home GDamaged vinyl siding trim
Home GSiding touching the ground
Home GSiding touching the roof
Home GSmall cracks in the brick veneer
Home GMissing or deteriorated exterior sealant
Home GDamaged, loose metal fascia wrap
Home GRusting steel lintels
Home GFailing window glazing in the laundry
Home GLoose rear door handle
Home GDamaged front door weather stripping
Home GScreen door closer detached
Home GDamaged rear door weather stripping
Home GBrick steps separating from the porch
Home GGround graded toward the house
Home GLong-term moisture damage at the fascia
Home HRotted siding and trim painted overSUMMARY
Home HRotted rear fasciaSUMMARY
Home HTree limbs touching the roofSUMMARY
Home HDamaged, loose garage door frameSUMMARY
Home HMissing or deteriorated exterior sealant
Home HLoose fascia board
Home HFogged windows with failed seals
Home HFront door lock hard to operate
Home HDamaged rear door weather stripping
Home HRear door missing strike plate and security screws
Home HGarage entry door missing security screws
Home HBrick steps separating from the porch
Home HLarge trees near the foundation
Home HGround graded toward the rear of the house
Home HLeaning, eroding brick retaining wall
Home IDamaged vinyl sidingSUMMARY
Home IMissing siding trimSUMMARY
Home IMissing or deteriorated exterior sealant
Home ILoose, damaged metal fascia wrap
Home IBuckling front soffit
Home IGaps in the metal fascia wrap
Home IDamaged window trim
Home IDeck boards damaged, loose or lifting
Home IDeteriorated garage door trim and weather stripping
Home JWalkway and steps sloped toward the houseSUMMARY
Home JGround sloped toward the house at the frontSUMMARY
Home JTree limbs touching the roofSUMMARY
Home JMissing or deteriorated exterior sealant
Home JMissing or damaged siding and trim at the rear
Home JLoose metal fascia wrap
Home JFogged window with a failed seal
Home JDoors needing strike and latch adjustment
Home JDamaged crawl space door
Home KDeck girders held on with nails onlySUMMARY
Home KGround graded toward the houseSUMMARY
Home KSiding trim installed improperly
Home KDoors missing hinge fasteners
Home KRough deck guardrail that can splinter
Home KLoose deck stair spindle
Home LWindow sills not sloped to shed waterSUMMARY
Home LDeck joists without joist hangersSUMMARY
Home LGround sloped toward the house at the frontSUMMARY
Home LBuckled, warped vinyl siding
Home LDamaged vinyl siding with gaps
Home LVinyl siding painted black
Home LSmall cracks in the brick
Home LLoose metal fascia wrap
Home LSide door missing hinge fasteners
Home LSide door missing weather-stripping
Home LGround graded toward the house
Electrical (126 defects · 12 of 12 homes)
HomeDefect
Home A100-amp service on an all-electric homeSUMMARY
Home AFrayed sheathing on the service entrance cableSUMMARY
Home ABreaker labels missing or illegibleSUMMARY
Home ABreakers of a different brand than the panelSUMMARY
Home ADouble-tapped breakerSUMMARY
Home AMissing wire grommet at the main panelSUMMARY
Home ANeutral and ground bonded in the kitchen subpanelSUMMARY
Home AExposed wiring in the laundry and kitchenSUMMARY
Home AOpen junction boxes and splices in the atticSUMMARY
Home ANo visible grounding electrode conductor at the meter
Home AOld generator disconnected and not working
Home ADamaged exterior light fixture
Home ABathroom recessed lights flickering
Home ALight switches on the far side of two rooms from the entry
Home AToo few outlets in several bedrooms
Home AMissing outlet cover plate in the kitchen
Home AUngrounded outlets in several rooms
Home BZinsco panelSUMMARY
Home BUndersized wire on a 20-amp breakerSUMMARY
Home BHVAC disconnect with multiple wires under one lugSUMMARY
Home BIndoor-rated cable exposed outsideSUMMARY
Home BMissing dead-front cover on the HVAC disconnect
Home B100-amp kitchen subpanel fed by a 70-amp breaker
Home BExterior outlet missing a weather cover
Home BRear light fixtures not working
Home BBedroom ceiling fan rocking in its mount
Home BLoose and open splices
Home BMost outlets ungrounded
Home CBreaker labels missing or illegible in the main and subpanelSUMMARY
Home CMissing knockouts in the main panelSUMMARY
Home CDouble-tapped breakerSUMMARY
Home CMissing wire grommet at the subpanelSUMMARY
Home CNeutral and ground bonded in the subpanelSUMMARY
Home CUndersized wire at a breakerSUMMARY
Home CIndoor-rated cable exposed outsideSUMMARY
Home COffice outlets not workingSUMMARY
Home CExposed wiring in the kitchenSUMMARY
Home COpen splices in the atticSUMMARY
Home CBedroom ceiling fan loose in its mountSUMMARY
Home CCut strands on stranded wiring in the main panel
Home CMissing outlet cover plate at the microwave
Home CBathroom light fixtures not working or missing
Home CWall switch installed upside down
Home COutlets ungrounded throughout
Home DMissing knockouts in the main panelSUMMARY
Home DMissing wire grommet at the main panelSUMMARY
Home DMost breaker labels missingSUMMARY
Home DUndersized wire on a 50-amp breakerSUMMARY
Home DNeutral and ground under the same lug in the main panelSUMMARY
Home DWiring lying on the crawl space soilSUMMARY
Home DUnsecured wiring at the attic accessSUMMARY
Home DDetached unit: nicked wire sheathing at the panelSUMMARY
Home DDetached unit: undersized knockout cap leaving a gapSUMMARY
Home DDetached unit: exposed wiring and junction boxesSUMMARY
Home DDetached unit: missing wire grommetSUMMARY
Home DDetached unit: neutral and ground bonded in the subpanelSUMMARY
Home DDetached unit: two-pole breaker with one wire cutSUMMARY
Home DDetached unit: exterior GFCIs and a switch not workingSUMMARY
Home DDetached unit: loose closet junction box with exposed wiringSUMMARY
Home DLoose laundry outlet
Home DToo few outlets in the master bedroom
Home DToo few outlets at the kitchen counters and island
Home DDamaged low-voltage box outside
Home DNo doorbell
Home DDetached unit: subpanel missing screws
Home DDetached unit: outlets missing cover plates
Home DDetached unit: two lights not working
Home EOutlets not working in a bedroom and outsideSUMMARY
Home EBreaker labels missing or illegible
Home ELight fixtures not working
Home EPorch ceiling fan rocking in its mount
Home FFaulty garage GFCI outletSUMMARY
Home FGround and neutral under the same lug in the garage main panel
Home FLight fixtures missing or not working
Home FOpen splices in the attic
Home G100-amp serviceSUMMARY
Home GBreaker labels missing or illegibleSUMMARY
Home GMissing wire grommet at the subpanelSUMMARY
Home GDouble-tapped garage subpanelSUMMARY
Home GMissing knockouts in the subpanelSUMMARY
Home GIndoor-rated cable exposed outsideSUMMARY
Home GExterior outlet missing a weather coverSUMMARY
Home GTwo outlets not workingSUMMARY
Home GTwo garage outlets wired with an open neutralSUMMARY
Home GLoose wire ends and open splices in the crawl spaceSUMMARY
Home GService entrance conductors not in conduit
Home GGround and neutral bonded in the garage subpanel
Home GWire too large for several breakers
Home GGround and neutral under the same lug in the main panel
Home GNeutral wires connected to the hot side of breakers
Home GLight fixtures not working
Home GLoose garage ceiling outlet
Home GGarage outlet wired with an open ground
Home GJunction boxes missing covers
Home GOutlets ungrounded throughout
Home GDoorbell not working
Home GAttic vent fan on an extension-type cord, not working
Home HDamaged, loose exterior outlet coverSUMMARY
Home HExposed wiring in the kitchenSUMMARY
Home HBedroom ceiling fan loose in its mountSUMMARY
Home HOutlet not workingSUMMARY
Home HHard-wired smoke detectors replaced with battery units; wiring left looseSUMMARY
Home HMain panel missing screws
Home HNo light switch at the base of the stairs
Home HMissing globe on a rear light fixture
Home HCloset light not working
Home HLoose living room outlet
Home IBreaker of a different brand than the panelSUMMARY
Home IPanel cover held on with sharp-tipped screwsSUMMARY
Home IDamaged wire sheathing in the main panelSUMMARY
Home IExposed wiring outside and in the garageSUMMARY
Home IBathroom light fixture not properly installedSUMMARY
Home IRodent activity in the garage electrical panel
Home ILoose electrical box at the front
Home ILoose exterior light fixtures
Home IRusted rear light fixture
Home IFlickering master bedroom fan light
Home IMissing closet outlet cover plate
Home JExposed wiring outsideSUMMARY
Home JLoose exterior light fixture
Home JOutlets two-prong or ungrounded throughout
Home KLoose wire strands in the subpanelSUMMARY
Home KMissing wire grommet at the subpanelSUMMARY
Home KSubpanel missing screws
Home LWire size not matched to its breakersSUMMARY
Home LTwo-prong or ungrounded outlets
Plumbing and water heaters (94 defects · 12 of 12 homes)
HomeDefect
Home ASulfur (“rotten egg”) odor in the hot waterSUMMARY
Home APEX lines unsupported, with a large stone resting on them
Home AMissing shower drain cover
Home ARibbed flex drains at three bathroom sinks
Home AWasher drain with no visible connection or discharge point
Home AOlder cast iron drain piping
Home ASink faucets flowing too hard for the sinks, splashing water
Home ADeteriorated grout and caulk at all showers and tubs
Home AHose bibs missing anti-siphon devices
Home BPEX supply lines next to the gas water heater flueSUMMARY
Home BPolybutylene supply pipingSUMMARY
Home BSaddle valve on the copper supply line
Home BLaundry P-trap over 24 inches long
Home BHose bibs missing anti-siphon devices
Home CWater heater relief valve discharge pipe missing or cut shortSUMMARY
Home CWaste line sloped backward in the crawl spaceSUMMARY
Home CLeaking front hose bibSUMMARY
Home CMaster and hall bath toilets loose at the floor
Home CTub diverter not shutting off the spout
Home DWater heater relief valve discharge pipe missingSUMMARY
Home DPEX supply lines not supported in the crawl spaceSUMMARY
Home DMaster and hall bath toilets without required clearanceSUMMARY
Home DDetached unit: leaking bathroom sink drainSUMMARY
Home DDetached unit: running toiletSUMMARY
Home DDetached unit: water heater relief valve discharge pipe missingSUMMARY
Home DKitchen faucet hot and cold reversed
Home DWasher drain still capped
Home DDetached unit: missing tub stopper
Home DDetached unit: deteriorated shower caulk
Home EMaster and hall bath toilets loose at the floor
Home EMissing floor drain cover
Home ELeaking master shower head
Home EChipped master tub/shower insert
Home EDeteriorated master shower caulk
Home EShower door missing its seal
Home ELoose hose bibs
Home EHose bibs missing anti-siphon devices
Home FDripping hot supply line in the laundrySUMMARY
Home FPolybutylene supply pipingSUMMARY
Home FDamaged plumbing vent stack in the atticSUMMARY
Home FWaste line improperly repaired and left openSUMMARY
Home FRibbed flex drain under a bathroom sinkSUMMARY
Home FS-trap under a bathroom sinkSUMMARY
Home FHalf-bath toilet heavily loose at the floorSUMMARY
Home FToilet that won’t stop runningSUMMARY
Home FShower head and arm loose in the wallSUMMARY
Home FDeteriorated shower grout and caulk, with past damageSUMMARY
Home FSlow master shower drain
Home FMissing sink stoppers
Home FLeaking, spraying shower head
Home FHalf bath sink stopper not working
Home FHose bibs missing anti-siphon devices
Home FLoose hose bibs
Home FDripping hose bib
Home FDamaged, cracked bathroom tile and grout
Home GPolybutylene supply pipingSUMMARY
Home GWeak water pressure throughoutSUMMARY
Home GRust staining at the main waste line, a sign of a leakSUMMARY
Home GStuck tub diverterSUMMARY
Home GLoose toilet seat
Home GDeteriorated hall shower grout and caulk
Home GChipped, damaged master tub/shower insert
Home GHose bibs missing anti-siphon devices
Home HCorroded connections on an aging water heaterSUMMARY
Home HLoose tub spout leaving a gap at the wallSUMMARY
Home HLoose hose bibsSUMMARY
Home HActive leak in the living room ceiling below the master bathSUMMARY
Home HUnsupported expansion tank
Home HExposed plumbing line near the cleanout
Home HMaster sink stopper not working
Home HDeteriorated master shower grout and caulk
Home HChipped master tub/shower insert
Home HHose bibs missing anti-siphon devices
Home ILeaking hall bath sink drainSUMMARY
Home IWater heater indoors with no drain pan
Home IBlack residue in the jetted tub
Home ISink stopper not working
Home ILow shower head pressure
Home ICracked master shower tile
Home ILoose hose bibs
Home IHose bibs missing anti-siphon devices
Home JWater heater relief valve discharge pipe missing or cut shortSUMMARY
Home JSink stopper not working
Home JMissing sink stopper
Home JHose bibs missing anti-siphon devices
Home JLoose hose bib
Home JDripping hose bib
Home KPlumbing vent stack cappedSUMMARY
Home KUnsealed gap at the shower glass letting water outSUMMARY
Home KLow pressure at the kitchen faucet
Home KTub stopper not working
Home KMissing caulk between the tub and tile floor
Home LFailing sealant at the rear hose bib
Home LRear hose bib not working
Interior finishes (91 defects · 12 of 12 homes)
HomeDefect
Home ANumerous cosmetic defects
Home AKitchen wall cabinets hung with the wrong fasteners
Home ACorner cabinet lazy Susan not working smoothly
Home ADoorstops missing throughout
Home ABedroom door rubbing at the jamb
Home ABedroom door not latching
Home AMissing bedroom closet door
Home BCabinet drawer hard to operate
Home BDoorstops missing in most rooms
Home BSeveral doors rubbing at the jamb
Home BBedroom door not latching
Home BMissing top latch on a French door
Home CNumerous cosmetic defects
Home CFloating floors buckled, lifting or warped
Home CWall cabinets installed incorrectly with the wrong fasteners
Home CUnfinished kitchen drawer with a loose handle
Home CCloset shelving pulling from the wall
Home CMost casement windows stuck or with damaged handles
Home DDetached unit: ceiling stain from past moistureSUMMARY
Home DNumerous cosmetic defects on walls and ceilings
Home DCabinet doors rubbing the refrigerator
Home DDoors with missing or improper fasteners
Home DBedroom door rubbing at the jamb
Home DHall closet door not latching
Home DAttic access panel not fitting its opening
Home DDetached unit: numerous cosmetic defects
Home DDetached unit: bedroom door with improper fasteners
Home EMissing glass pane in a dining room windowSUMMARY
Home ENumerous cosmetic defects
Home EFloating floors buckled, lifting or warped in many rooms
Home ECloset shelving pulling from the wall
Home ECabinets hung with the wrong fasteners
Home ECabinet doors not level
Home EMissing cabinet shelf support
Home EMissing doorstops
Home EMaster bedroom door not latching
Home ELoose closet door knob
Home EDamaged hall bath door
Home ECloset door rubbing
Home EDoor knobs sticking
Home EDamaged window tilt hardware
Home FNumerous cosmetic defects
Home FCabinets in the garage and laundry installed incorrectly
Home FTowel and toilet paper holders pulling from the walls
Home FPantry shelving pulling from the wall
Home FKitchen cabinets and drawers not working smoothly
Home FDoors swinging closed on their own
Home FDoors rubbing at the jamb
Home FBedroom door missing fasteners
Home FDoorstops missing in most rooms
Home FWindow sashes not aligning
Home FDamaged window tilt hardware
Home GWater stains on the garage wall panelingSUMMARY
Home GNumerous cosmetic defects
Home GBathroom drawer rubbing
Home GDoors rubbing at the top
Home GDoorstops missing throughout
Home GLoose door knobs
Home GMaster bedroom door rubbing
Home GMaster bedroom window hard to operate
Home GPorch attic ladder not cut to fit the floor
Home GAttic ladder missing its pull string
Home HNumerous cosmetic defects
Home HFloating floors buckled, lifting or warped on both floors
Home HLoose or damaged towel and toilet paper holders
Home HDamaged closet shelving
Home HKitchen cabinets hung with the wrong fasteners
Home HLoose kitchen drawer
Home HCloset door not latching
Home HFrench doors rubbing
Home HWindows hard to operate
Home INumerous cosmetic defects
Home IFloating floors buckled, lifting or warped
Home IDoors not latching
Home IDamaged attic access lid
Home JNumerous cosmetic defects
Home JKitchen cabinets hung with the wrong fasteners
Home JDoors rubbing at the jamb
Home JCloset doors dragging on the floor
Home KNumerous cosmetic defects
Home KMaster bath drawer installed incorrectly
Home KBedroom door rubbing
Home KHall bath door not latching
Home KLoose door knobs
Home KMissing doorstops
Home KDoors missing screws
Home LCracked, loose ceiling drywall in the kitchenSUMMARY
Home LNo attic access to the left attic
Home LNumerous cosmetic defects
Home LDoors not latching
Home LBedroom door rubbing
Structure and foundation (82 defects · 12 of 12 homes)
HomeDefect
Home AFoundation cracking, gaps and movement at many locationsSUMMARY
Home AJoist hangers missing fasteners or installed with wood screwsSUMMARY
Home AExtensive earlier repairs to the floor system with inconsistent connectionsSUMMARY
Home ATemporary wood support posts in the crawl spaceSUMMARY
Home AAdded dry-stacked brick and block piers leaning and settlingSUMMARY
Home ASubflooring lifting and sagging in several rooms
Home AOlder floor joists held to beams mainly with toe-nails
Home AOlder roof framing with no ridge board; rafters separating
Home AOriginal roof framing and shingles left in the attic under an addition
Home BBrick and block foundation cracking from long-term settlementSUMMARY
Home BFloor joists and beams shifted, with gaps at their supportsSUMMARY
Home BMain beams cut and notched for drain linesSUMMARY
Home BEarlier floor repair under the hall bath with improper hanger fastenersSUMMARY
Home BCut floor joist sagging at the front rightSUMMARY
Home BAdded block piers with no footing and no mortarSUMMARY
Home BOriginal brick piers cracked and deterioratedSUMMARY
Home BRoof ridge repair over a removed chimney, with a gap and wood screwsSUMMARY
Home BCracked, shifting rafter near the old chimneySUMMARY
Home BRafters twisted, cut short or poorly connectedSUMMARY
Home BFloor joists toe-nailed to their supports
Home BPast wood-destroying organism activity on floor joists
Home CCracked, displaced brick foundation wall at the front porchSUMMARY
Home CFloor joists not properly attached at the front rightSUMMARY
Home CDamaged, buckled truss gusset platesSUMMARY
Home CTwo split rafters and a buckled supportSUMMARY
Home DLedger strip unsupported at a pier and saggingSUMMARY
Home DFloor joists not attached with hangers or ledger stripsSUMMARY
Home DCracked center beamSUMMARY
Home DRear beam cut at the topSUMMARY
Home DSloping floors along the front of the houseSUMMARY
Home DAdjustable steel columns supporting the floorSUMMARY
Home DRoof framing missing supports at the ridge and rafter basesSUMMARY
Home DTree roots growing into the crawl space
Home DSubflooring missing or deteriorated at the rear of the crawl space
Home EWidening cracks in the foundation and brick veneerSUMMARY
Home ERear roof support posts poorly installed and movingSUMMARY
Home ERafters with gaps, twisting and crackingSUMMARY
Home FLarge gaps where rafters meet throughout the atticSUMMARY
Home FCracks in the garage concrete
Home FCracked block foundation at the crawl space entry
Home FSubflooring popping, creaking or sagging
Home GCracked, displaced block foundation wallsSUMMARY
Home GFloor joist cut under the hall bath; joist hangers missingSUMMARY
Home GLedger strip missing nailsSUMMARY
Home GTemporary wood support posts in the crawl spaceSUMMARY
Home GCracked truss members in the atticSUMMARY
Home GFloor joists at the front with gaps, sagging or shifting
Home GFloors popping, creaking or sagging in several places
Home GPast wood-destroying insect activity in the garage walls
Home HWidening crack in the brick and slabSUMMARY
Home HDamaged, disconnected gusset plates along the ridgeSUMMARY
Home HExterior cracks
Home HUpstairs floors popping, creaking or sagging
Home IDamaged, twisting truss members and gusset platesSUMMARY
Home IBonus room subfloor popping, creaking or sagging
Home JCracked, displaced brick and block foundation wallsSUMMARY
Home JBlock foundation wall damaged for plumbing linesSUMMARY
Home JTemporary wood support posts in the crawl spaceSUMMARY
Home JAdded piers with no footing, blocks on their side and no mortarSUMMARY
Home JRafters twisted, with gaps where they meetSUMMARY
Home JRafter cut through around a plumbing ventSUMMARY
Home JEvidence of past wood-destroying insect activitySUMMARY
Home JSubfloors popping, creaking or sagging in many rooms
Home JFloor joist cut by a tradesman under the hall bath
Home KMain beams repaired outside standard practice, with gapsSUMMARY
Home KMain beams missing joist hangers or ledger stripsSUMMARY
Home KMain beams cut under the master bathSUMMARY
Home KLoose board on a pier not bearingSUMMARY
Home KAdded block piers with blocks on their side and too little mortarSUMMARY
Home KGaps at rafter connections and earlier repairsSUMMARY
Home KMissing rafter supports at a valleySUMMARY
Home KRafters twisted and damagedSUMMARY
Home KCracks in the concrete foundation wall
Home KSubfloors popping, creaking or sagging in many rooms
Home LHorizontal cracking and movement in the brick foundationSUMMARY
Home LPast or present wood-destroying insect damage in the floor systemSUMMARY
Home LFloor framing sagging under a bedroomSUMMARY
Home LJoist hangers installed incorrectlySUMMARY
Home LFloor joists cut under the living roomSUMMARY
Home LBrick piers leaning and unsupportedSUMMARY
Home LAdjustable steel columns supporting the floorSUMMARY
Home LLong-term moisture damage to rafters and sheathing at the chimneySUMMARY
Ventilation and insulation (69 defects · 12 of 12 homes)
HomeDefect
Home ABath exhaust fans not vented to the outsideSUMMARY
Home AFlex dryer vent that traps lintSUMMARY
Home ADamaged gable vent screenSUMMARY
Home AAttic insulation installed upside downSUMMARY
Home AScreen on the dryer vent hood; hood not flush with the house
Home AOld, unused dryer vent hood left in place
Home AFoundation vents at or near ground level
Home ALoose, damaged foundation vents
Home AAttic insulation missing, thin or old
Home AUninsulated attic access
Home AFloor system not insulated
Home BDryer not vented to the outsideSUMMARY
Home BHall bath fan not vented to the outsideSUMMARY
Home BDryer vent stuck open
Home BNo exhaust fan in the hall bath
Home BLoose foundation vents
Home BAttic insulation missing or thin in most areas
Home BUninsulated pull-down attic stairs
Home BFloor system not insulated
Home CBath fans not vented to the outsideSUMMARY
Home CLoose dryer vent hood
Home CFoundation vent screens missing or damaged
Home CAttic insulation thin and uneven
Home CUninsulated attic access
Home CFloor system not insulated in areas
Home DDryer vent too close to the groundSUMMARY
Home EDryer vent loose in the attic, with an improper roof ventSUMMARY
Home ERodent activity in the attic insulation
Home ECompressed attic insulation
Home EAttic insulation missing in areas, leaving framing exposed
Home EUninsulated attic access
Home FDirty dryer ventSUMMARY
Home FBath fans not vented outside; one vent pipe crushedSUMMARY
Home FDamaged dryer ventSUMMARY
Home FAttic vent fans not workingSUMMARY
Home FLoose foundation vents
Home FRodent activity in the attic insulation
Home FAttic insulation compressed, displaced or missing
Home FCrawl space insulation damaged by rodents
Home GFlex dryer vent that traps lintSUMMARY
Home GCrawl space insulation installed upside downSUMMARY
Home GHall and master bath fans not vented to the outside
Home GDamaged foundation vent screens and flaps
Home GAttic insulation uneven and missing in areas
Home GUninsulated attic ladder
Home GMost of the floor system not insulated
Home HMissing flapper on an exhaust vent hoodSUMMARY
Home HHall bath fan not vented to the outsideSUMMARY
Home HDamaged gable vent screensSUMMARY
Home HRodent activity in the attic
Home HAttic insulation compressed or missing
Home HDamaged, displaced batt insulation
Home HUninsulated attic access
Home IDisplaced insulation and air leakage in three roomsSUMMARY
Home IDamaged dryer vent
Home IBath fans not vented directly outside
Home IMissing attic insulation baffles
Home ICompressed attic insulation
Home IUninsulated attic access
Home JFoundation vents closed off
Home JCompressed attic insulation
Home KExposed insulation under the rear overhangSUMMARY
Home KScreen on the dryer vent hood
Home KLoose crawl space vent
Home KDisplaced attic insulation baffle
Home KCrawl space floor insulation damaged by moisture
Home LDamaged gable vent screenSUMMARY
Home LLoose foundation vents
Home LLow spots in the attic insulation
Heating, cooling and gas (57 defects · 11 of 12 homes)
HomeDefect
Home ACondensate line not routed away from the house
Home AOutdoor AC unit not level
Home ADirty air filters
Home BRust and corrosion in the furnace housingSUMMARY
Home BGas water heater not level; flue pipe leaning
Home BRusted gas connections with failing sealant at the meter
Home BTorn, deteriorated duct insulation in the crawl space
Home BAbandoned duct openings left in the floor system
Home COutdoor condenser coils bent and restrictedSUMMARY
Home CDamaged ductwork lying on the crawl space floorSUMMARY
Home CRusted gas connections with failing sealant at the meter
Home CDeteriorated fireplace firebrick
Home CDamaged, buckled hallway supply register
Home DMissing condensate drain extension at the package unitSUMMARY
Home DPackage unit ductwork not sealed to the house
Home DDetached unit: missing supply register cover
Home EGas furnace vent poorly venting, with a failing repairSUMMARY
Home ERusted gas connections with failing sealant at the meter
Home ERusting drain pan under the HVAC unit
Home EStone mantel removed from a gas log fireplace
Home ECondensate line not routed away from the house
Home EMissing insulation on the AC suction line
Home EDirty condenser coils
Home EDirty air filters
Home FUpstairs air conditioning not cooling within the normal rangeSUMMARY
Home FRust and corrosion in the furnace burner area
Home FHVAC system past its typical life expectancy
Home FBent, dirty condenser coils
Home FMissing insulation on the AC suction line
Home FDirty ductwork
Home FFilter access not sealing
Home GGas water heater closed in with no combustion airSUMMARY
Home GMissing drip legs on the gas linesSUMMARY
Home GHVAC system past its typical life expectancy
Home GFurnace intake missing a pest cover
Home GSecond HVAC system past its typical life expectancy
Home GDirty ductwork
Home GDamaged duct insulation and failing tape in the crawl space
Home HAir conditioning not cooling within the normal rangeSUMMARY
Home HMissing drip leg on the water heater gas line
Home HDeteriorated fireplace firebrick
Home HHVAC system past its typical life expectancy
Home HMissing insulation on the AC suction line
Home HOne system and thermostat serving two floors
Home HDirty air filters
Home IGas odor at the furnace connectionSUMMARY
Home IFlue pipes too short for their distance to the ridgeSUMMARY
Home IRusted gas connections with failing sealant at the meter
Home IRust and corrosion in the furnace burner housing
Home IHVAC system past its typical life expectancy
Home IOne system and thermostat serving two floors
Home KNo secondary condensate drains or cleanouts on the heat pumps
Home KCondensate line not routed near the ground
Home LAbandoned duct left open to the crawl spaceSUMMARY
Home LRusted gas connections with failing sealant at the package unit
Home LDisconnected condensate line
Home LDamaged duct insulation in the crawl space
Roof, flashing and gutters (51 defects · 12 of 12 homes)
HomeDefect
Home AGutter sloped incorrectly at the frontSUMMARY
Home ANewer 3-tab shingles curling and lifting
Home ANo gutters along the sides and rear
Home ADownspouts missing extensions at the foundation
Home AMissing kick-out flashing at a roof-to-wall joint
Home AStep flashing pulling away at the rear
Home BNo gutters on the left side
Home BDownspouts missing extensions at the foundation
Home CGutter sloped incorrectly
Home CLeaking gutter seams
Home CGutter touching the siding
Home CGutters full of debris
Home CChimney missing a pest screen
Home DArchitectural shingles on a roof section too low-sloped for themSUMMARY
Home DRear downspout detached from the houseSUMMARY
Home DDownspouts missing extensions at the foundation
Home DCracked chimney crown
Home DChimney flues missing caps and screens
Home DDamaged old chimney clean-out door
Home DDetached unit: debris built up on the carport roof
Home ERear addition roof too low-sloped for its shingles
Home EGutters full of debris
Home ELeaking gutter seams
Home FMissing flashing at the front roofSUMMARY
Home FDownspouts missing extensions at the foundation
Home FDownspouts pulling from the wall
Home FExposed fasteners at headwall flashing
Home FMissing kick-out flashing
Home FStaining on the roof sheathing and rafters around the chimney
Home GDownspout loose and disconnectedSUMMARY
Home GPlumbing vent flashing liftingSUMMARY
Home GGutter brackets pulling away
Home GDownspouts missing extensions at the foundation
Home GLeaking gutter seams
Home GCracked, deteriorated chimney crown
Home GMissing chimney cap
Home HLoose downspoutSUMMARY
Home HDownspout buried at grade
Home HMissing kick-out flashing
Home IFailing flue flashingSUMMARY
Home ISigns of earlier shingle repairs
Home IShingles and flashings near the end of their service life
Home IMissing headwall flashing
Home JGutter sloped incorrectly
Home JDamaged gutter with brackets pulling away
Home JDownspouts missing extensions at the foundation
Home JDownspout splice collecting debris; missing elbow
Home JLeaking gutter seams
Home KShingles installed with exposed nailsSUMMARY
Home LGutter brackets pulling awaySUMMARY
Home LDownspouts missing extensions at the foundation
Safety (48 defects · 11 of 12 homes)
HomeDefect
Home ASmoke detectors missing in bedrooms and a hallwaySUMMARY
Home AWet-location outlets not GFCI protected
Home BNo carbon monoxide detectorSUMMARY
Home BRear door opening over the steps
Home BFront entry step taller than normal
Home BLaundry outlets not GFCI protected
Home CLoose handrails at the front stepsSUMMARY
Home CBathroom and wet-area outlets not GFCI protectedSUMMARY
Home CSmoke detectors missing in bedroomsSUMMARY
Home CUneven, deteriorated driveway creating a trip hazard
Home DFront steps with four or more risers and no handrail
Home DRear deck with no safety rails
Home DOnly one smoke detector, in the hallway
Home DDetached unit: loose stair handrail
Home ENo carbon monoxide detectorSUMMARY
Home ESmoke detectors missing in a bedroom and hallwaySUMMARY
Home EDamaged window sash springsSUMMARY
Home ELaundry outlets not GFCI protected
Home FKeyed deadbolt on a rear doorSUMMARY
Home FFire separation between the garage and the house compromisedSUMMARY
Home FLaundry, bathroom and exterior outlets not GFCI protectedSUMMARY
Home FNo carbon monoxide detectorSUMMARY
Home FSmoke detectors missing in all bedroomsSUMMARY
Home FSeparated, uneven front walkway creating a trip hazard
Home FGarage door safety sensors improperly installed
Home FGarage door opening over the steps
Home GSmoke detectors missing in bedroomsSUMMARY
Home GHandrails missing at the rear stepsSUMMARY
Home GRotted handrail posts at the front and side stepsSUMMARY
Home GDeck door opening over the steps with no landingSUMMARY
Home GGarage doors missing spring retention cablesSUMMARY
Home GNo landing outside the garage door stairs
Home GGarage and laundry outlets not GFCI protected
Home GTwo windows missing locks, not staying closed
Home GWeak, unstable attic ladder
Home HGarage door safety sensors not connectedSUMMARY
Home HSmoke detectors missing in bedroomsSUMMARY
Home HNo carbon monoxide detectorSUMMARY
Home HUneven front walkway creating a trip hazard
Home HLaundry outlet not GFCI protected
Home HGuardrail balusters spaced too far apart
Home IGarage door opener not reversingSUMMARY
Home IFire separation between the garage and the house compromisedSUMMARY
Home IDamaged window sash springsSUMMARY
Home JLaundry outlets not GFCI protected
Home JSmoke detector too close to the kitchen
Home JAttic ladder not cut to fit, weak and unstable
Home LLoose guardrails at the front stepsSUMMARY
Moisture and microbial growth (33 defects · 11 of 12 homes)
HomeDefect
Home AMicrobial growth on the crawl space framingSUMMARY
Home AVapor barrier missing in over half the crawl space, with elevated moistureSUMMARY
Home BMicrobial growth on the crawl space framingSUMMARY
Home BDark stains on the brick foundation
Home BVapor barrier deteriorated and missing in areas
Home CFloor joists and supports cupped and decayed from long-term moistureSUMMARY
Home CDark stains and efflorescence on the brick foundationSUMMARY
Home CMicrobial growth on the crawl space framingSUMMARY
Home CVapor barrier deteriorated in areas
Home DDark stains on the brick foundationSUMMARY
Home DMicrobial growth on the crawl space framingSUMMARY
Home DCrawl space vapor barrier missingSUMMARY
Home FDark stains and efflorescence on the block foundationSUMMARY
Home FMicrobial growth on the crawl space framingSUMMARY
Home FMicrobial growth in the structure at the half bath
Home FSigns of past leaks in the floor system under the master bath
Home FStaining and past moisture damage under the kitchen and hallway
Home FWet stains on upstairs baseboards
Home GMicrobial growth on the crawl space framingSUMMARY
Home GFloor joists and subfloor stained and deteriorated from moisture
Home GDark stains on the block foundation
Home HMicrobial growth in the structure in several areas
Home IDark stains on the brick and concrete
Home JDark stains and efflorescence on the block foundationSUMMARY
Home JMicrobial growth on the crawl space framingSUMMARY
Home JMicrobial growth in the structure in several areas
Home JVapor barrier deteriorated in areas
Home KDark stains and efflorescence on the brick foundationSUMMARY
Home KMicrobial growth on the crawl space framingSUMMARY
Home KCrawl space vapor barrier displacedSUMMARY
Home LDark stains and efflorescence on the brick foundationSUMMARY
Home LMicrobial growth on the crawl space framingSUMMARY
Home LVapor barrier missing in areas
Kitchen appliances (16 defects · 9 of 12 homes)
HomeDefect
Home ARange not anchored against tipping
Home ARefrigerator unusually loud
Home BDishwasher not secured to the cabinet
Home COven not workingSUMMARY
Home CDamaged microwave with filter inserts missing
Home DRange hood filters not installed
Home EDishwasher drain hose not looped or air-gapped
Home FStove not working (C-d0 error)SUMMARY
Home FRange not anchored against tipping
Home FRange hood missing its filter
Home FIce maker not producing ice
Home GRange not anchored against tipping
Home GOven smoking heavily
Home HGarbage disposal not workingSUMMARY
Home IRange hood light not working
Home IRange hood missing its filter

Common questions about flipped home inspections

Should I get a home inspection on a flipped home?

Yes. All 12 flipped homes in this study had structural, electrical, plumbing and exterior problems, and most of the serious ones were hidden in the crawl space, the attic and the electrical panel. New finishes don’t tell you whether the work underneath was done right.

What problems do inspectors find most often in flipped homes?

In these 12 homes: structural repairs not done to standard, like temporary posts and dry-stacked piers; moisture and microbial growth in crawl spaces; panel and wiring defects; old polybutylene supply piping; leaks; and new finishes and appliances installed incorrectly.

Can a home inspection tell me if the work was permitted?

A home inspection doesn’t verify permits, but it does document work that wasn’t done to standard practice. When we flag structural, electrical or plumbing repairs, ask the seller for permits, invoices and any engineer’s letters.

How long does it take to get my report?

Every AHI report is proofread and customized to the home, with photos like the ones above. Reports can take up to 72 hours, and if you attend the inspection, your inspector will give you an estimated delivery time.

Thinking about buying a flipped home?

Look beyond the renovations before you invest. AHI Residential and Commercial Inspections has been inspecting homes across Charlotte and the surrounding area for more than 20 years, backed by a 100% satisfaction guarantee.

Or call 866-356-2363